Blue Phantom obese lumbar epidural and lumbar puncture replacement tissue insert

For use with our Spinal Epidural and Lumbar Puncture training models (P/N BPLP2101).  The accessory obese replacement module is excellent in its realism, quality and durability offering users the ability to utilize ultrasound or blind insertion techniques while performing lumbar puncture or lumbar epidural procedures to access the epidural or subarachnoid space.   The accessory obese spinal insert provides more adipose tissue disallowing the palpation of the spinal processes. This module is superb for needle access as well as the placement of catheters.

Extremely realistic and self-healing design offers you superb training with a low cost of ownership.

The obese lumbar epidural and lumbar puncture replacement tissue module is superb in its realism and contains the entire lumbar spine, skin tissue, ligamentum flavum, epidural space, dura, subarachnoid membrane, and subarachnoid cistern containing cerebral spinal fluid (CSF).  Users can inject local anaesthetics, introduce the needle to the epidural space and/or subarachnoid space (performs “spinal taps”), thread catheters, infuse simulated anaesthetics, and obtain manometer measurements – all while experiencing a realistic tissue response including the pop encountered when traversing the ligamentum flavum, loss of resistance when entering the epidural space, and cerebral spinal fluid flow when the spinal cistern is accurately accessed.  The cerebral spinal fluid pressures can be easily increased in order to simulate pathological scenarios.

The obese lumbar epidural and lumbar puncture insert is designed using Blue Phantom ultra-durable and self-healing tissue.  Our durability provides you with optimal training at a low cost of ownership.

Use any ultrasound system and never have to adjust the system settings unrealistically or have problems imaging the model’s anatomy.

Our patented tissue is extremely realistic – both imaging and feeling like real human tissue.  Blue Phantom synthetic tissue matches the acoustic characteristics of real human tissue so when you use your ultrasound system on our training models, you experience the same quality you expect from imaging patients in a clinical environment.  Blue Phantom obese lumbar epidural and lumbar puncture replacement insert will perform well using any ultrasound imaging system configured with the appropriate ultrasound transducer.

Specifications

  • Excellent training platform for lumbar puncture and lumbar epidural procedures
  • Excellent for blind insertion techniques or using ultrasound for guided spinal epidural or lumbar puncture procedures
  • Superb for needle access as well as the placement of catheters
  • The accessory obese spinal epidural and lumbar puncture insert provides more adipose tissue disallowing the palpation of the spinal processes
  • Obese lumbar epidural and lumbar puncture tissue module is superb in its realism and contains the lower thoracic and lumbar spinal segment, skin tissue, ligamentum flavum, epidural space, dura, subarachnoid membrane, and subarachnoid space containing cerebral spinal fluid
  • Utilize for full procedural training including injecting local anaesthetics, introduce the needle to the epidural space and/or subarachnoid space, thread catheters, infuse simulated anaesthetics, and obtain manometer measurements
  • Realistic tissue response including the pop encountered when traversing the ligamentum flavum, loss of resistance when entering the epidural space, and cerebral spinal fluid flow when the spinal cistern is accurately accessed.
  • Extremely durable and is self-healing which saves you money by reducing the need to repeatedly purchase replacement parts
  • All injected fluids are automatically expelled and cerebral spinal fluid that is removed is easily refilled using quick refill ports
  • Ultrasound can be used for identification of the optimal insertion points, angle of needle insertion, and determination of the depth to the ligamentum flavum, epidural space, and spinal cistern
  • Superb ultrasound imaging characteristics
  • Use any ultrasound system and never have to adjust the system settings unrealistically or have problems imaging the model’s anatomy
  • Ultra-durable self-healing tissue is extremely realistic in ultrasound imaging characteristics and feels like real human tissue
  • Self-healing tissue will withstand tremendous use and will save you money by dramatically reducing the necessity for purchasing replacement parts
  • Patented technology
  • Made in USA
  • For use with: Blue Phantom Spinal Epidural and Lumbar Puncture Training Models (BPLP2101, BPLP2102, BPLP2103)
  • Size: 9” x 7” x 4” (23cm x 18cm x 10cm) (L x W x H)
  • Weight: 14 lbs. (6.4kg)
Sim & Skills accepts NHS, Government, and University Purchase Orders