🎄🎅 We will be closed from 24th Dec until 2nd Jan 🎅🎄

🚨 Get free delivery with this code today!

FREESHIP

Gen II Femoral Vascular Access and Regional Anaesthesia Ultrasound Training Model

Blue Phantom by Elevate Healthcare  |  SKU: BPF1500-HP
£5,07600

Safety & Quality

👉 This product is for training purposes only.

✅ This product is Latex-free.

✅ Sim & Skills is ISO 9001 certified.

✅ Available via NHS Supply Chain.

Delivery

When will my order arrive?

Items listed as In Stock are usually delivered in 1-3 working days.

Due to global supply chain disruption, some products are taking longer to deliver. If your order is affected, we will inform you as soon as possible with an estimated lead time or an alternative product recommendation.

For urgent or high volume orders, please contact us before placing your order to check stock availability.

How much does delivery cost?

Tracked Delivery on website orders to a single Mainland Great Britain address is charged at £7.50 + VAT.

Tracked Delivery on purchase orders to a single Mainland Great Britain address is charged at £15.00 + VAT.

Shipping to Northern Ireland and British Forces is charged at £25.00 + VAT.

Palletised deliveries are charged at £85.00 + VAT per pallet.

Deliveries will be made to a Goods In area not a specific room/department.

International shipping is provided on a case-by-case basis, please contact us for a quote.

Returns

What is the returns policy?

Returns are acceptable within 28 days of delivery (by law you have 14 days to notify us and a further 14 days to complete the return), providing the item is in a resalable condition and in its undamaged original packaging.

Cancellations and Returns are free of charge for items up to 20 kg. Collection for items over 20 kg will be quoted on a case-by-case basis.

All returns must be pre-authorised prior to shipping. Unauthorised returns may be refused and additional carriage costs may be incurred.

Failure to return goods in a resalable condition may result in a restocking fee of £25.00 + VAT or 20% of the invoice value, whichever is greater.

Any goods returned for product defect or warranty issues will not incur a restocking fee, but must still have appropriate authorisation.

To start a return, email orders@simandskills.com.

If your return is accepted, we’ll send you a return shipping label and instructions on how and where to send your package. Items sent back to us without first requesting a return will not be accepted.

Description

Gen II Femoral Vascular Access and Regional Anaesthesia Ultrasound Training Model

Blue Phantom’s Generation II Femoral lower torso ultrasound guided regional anaesthesia and central venous access training model is an excellent tool to train users to develop and practise the skills necessary to gain proficiency in using ultrasound for regional anaesthesia procedures of the femoral nerve, as well as guide catheter insertions in the femoral artery and vein. 

Built upon the feedback we received from our customers of our first-generation femoral model, we have developed the most realistic Femoral Ultrasound trainer available in the market today.

Using Blue Phantom simulated human tissue, this very realistic and ultra-durable ultrasound training phantom is an excellent choice for training clinicians in the psychomotor skills associated with ultrasound-guided regional anaesthesia as well as vascular access procedures. 

These ultrasound imaging skills include; using ultrasound system controls, transducer positioning and movement, recognition of nerves, arterial and venous anatomy, using ultrasound to target the femoral nerves for regional anaesthesia procedures, guide needles to blood vessels for cannulation, and performing vascular access procedures.

Comprised entirely of our patented Simulex self-healing tissue, users can access vessels on both limbs resulting in twice the number of access sites compared to the original model.

With our innovative new hand pump system, the femoral artery no longer collapses creating our most realistic anatomy yet.

We know that gaining the psychomotor skills to perform ultrasound-guided procedures requires practise.  Our ultra-durable self-healing tissue will allow you to repeatedly perform ultrasound-guided regional anaesthesia nerve blocks and central venous access procedures without giving a second thought to who or when you train or calculate the cost for each training session. 

Whether you are learning to use ultrasound to guide needles, perform nerve blocks and vascular access procedures, or troubleshoot difficult catheter placements, you can expect unmatched durability from our nerves, tissue and vessels.

Blue Phantom ultrasound training manikins are constructed using patented ultra-durable tissue and are extremely realistic in ultrasound imaging characteristics and feels like real human tissue. 

Our self-healing tissue will withstand tremendous use and will save you money by dramatically reducing the necessity for purchasing replacement parts.


Realism makes your training better.

Each model offers anatomically correct femoral nerve as well as the fascia iliaca nerve. Vascular anatomy as well as anatomical landmarks of the lower torso. 

Vascular Anatomy includes:

  • Aorta
  • Inferior Vena Cava (IVC)
  • Common Iliac Artery and Vein
  • Internal Iliac Artery and Vein
  • Femoral Artery and Vein
  • Great Saphenous Vein.

Users can utilise traditional anatomical landmarks such as the Pubic symphysis, Iliac Crest and Inguinal Ligament for blind venous access insertion techniques, or utilise ultrasound to obtain images of pertinent anatomical structures. 

The model is equipped with a hand pump used to create arterial pulsations which can help users differentiate between arteries and veins as well as providing internal reference points for regional anaesthesia procedures.

Positive fluid flow in the vessels provides users with immediate feedback when vessels are accessed. 

Simulated anaesthetics can be injected into the manikin to aid the user in learning to perform the entire ultrasound-guided nerve block procedure.

Injected fluids are automatically expelled so that the model can be used repeatedly for training. 

The colour of the simulated blood fluids in the arterial vessels differs from the venous system allowing users to easily differentiate between successful venous access procedures.

Collapsible Venous anatomy with mild pressure also aids in distinguishing the artery from the vein.

Venous and arterial fluids that are removed during central catheter insertions training are easily refilled using quick fill ports.

While performing vascular access central catheter procedures, internal vessels accommodate the full threading of guidewires and catheters. 

Our tissue looks, feels, and images like human tissue. 

At Blue Phantom, we expend tremendous effort to match the imaging characteristics of real human tissue allowing you to teach and train under optimal conditions. 

We know that the best simulation training scenarios are requisite for users experiencing the same procedural realism as performing the procedure on patients. 

All of our simulation materials match the acoustic characteristics of real human tissue so when you use your ultrasound system on our training models, you experience the same quality you expect from imaging patients in a clinical environment.

Use your own ultrasound system for simulation training.  This medical simulation trainer will perform well using any ultrasound imaging system configured with the appropriate transducer (recommended ultrasound transducer; high-frequency linear array ultrasound probe 5.0–12 MHz). 

This ultrasound phantom model is excellent for specialities including anaesthesiology, cardiology, emergency medicine, radiology, surgery, surgical training programs, ultrasound training programs, simulation centres, surgical skills centres, medical education facilities, and ultrasound manufacturers for ultrasound education and demonstrations.  

Specifications

  • Ultrasound-guided regional anaesthesia and central venous access ultrasound training model
  • Regional anaesthesia; contains the femoral nerve and its branches along with the Saphenous Nerve and Fascia Iliaca Nerve.
  • Central venous access; contains anatomically correct vascular anatomy of the right lower torso including the femoral artery and vein, Aorta, IVC, Common Iliac Artery and Vein, Internal Iliac Artery and Vein, Great Saphenous Vein, Simulated DVT (Deep Vein Thrombosis) in the lower Right Femoral Vein.
  • Inject simulated anaesthetics to verify needle tip location and to practice the entire regional anaesthesia procedure
  • Anatomical landmarks include Pubic Symphysis, Iliac Crest and Inguinal Ligament for palpation. 
  • Use 18-21 gauge needles and 7 French Catheter to access the venous system.
  • Use repeatedly; injected simulated anaesthetics are automatically expelled
  • Superb ultrasound imaging characteristics; learn to acquire and interpret ultrasonographic imaging of nerves and vessels
  • New Blue Phantom Integrated Hand pump to create pulsatile arteries with a slow return to allow collapsing of the venous system
  • Self-healing tissue will withstand tremendous use and will save you money by dramatically reducing the necessity for purchasing replacement parts
  • Utilise traditional anatomical landmarks for blind insertion techniques, or utilize ultrasound to obtain images of anatomical structures
  • Accommodates full threading of guidewires and catheters
  • Venous and arterial fluids that are removed during central catheter insertions training are easily refilled using quick fill ports
  • Positive fluid flow in the vessels provides users with immediate feedback when vessels are accessed
  • Simulated blood fluids in the arterial vessels differ from the venous system allowing for users to easily verify successful venous access procedures
  • Tissues match the acoustic characteristics of real human tissue so when you use your ultrasound system on our training models, you experience the same quality you expect from imaging patients in a clinical environment
  • Performs well using any ultrasound imaging system
  • Practise using ultrasound system controls
  • Purchase includes 2 bottles of simulated blood refill solution; one red (arterial), one blue (venous). 235mls bottles
  • The model comes with Thermoform Platform to keep the model in place and for storage purposes.
  • High quality
  • No special storage needs
  • Patented technology
  • Made in USA
Gen II Femoral Vascular Access and Regional Anaesthesia Ultrasound Training Model User Manual - Sim & Skills

Specifications

  • Manufacturer's Warranty
    1 Year

Reviews (0)

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Payment & Security

Secure payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store or have access to your credit card details.

Purchase Orders

We accept purchase orders from public and government authorities including the NHS and Universities subject to our terms of business.

Click Add to Quote to easily build your quote ➡️

Welcome to Shopify Store

I act like: