Skip to content

Leg Femoral and Saphenous Vein Venous Access Ultrasound Training Model with DVT Option

SKU BPL400
Original £4,164.00 - Original £4,368.00
Original
£4,164.00 Inc.VAT
£4,164.00 - £4,368.00 Inc.VAT
Current price £4,164.00 Inc.VAT
£3,470.00 Exc.VAT
DVT: No DVT

Customer Reviews

No reviews yet
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Blue Phantom’s leg vascular access ultrasound training model allows users to develop and practice the skills necessary to gain proficiency in using ultrasound to guide needle and catheter insertions in the saphenous and femoral vein. 

Using Blue Phantom proprietary simulated human tissue, this very realistic and ultra-durable venous access ultrasound training mannequin is excellent for training clinicians in the psychomotor skills associated with ultrasound-guided vascular access procedures. 

These ultrasound imaging skills include; using ultrasound system controls, transducer positioning and movement, recognition of venous anatomy, using ultrasound to target the appropriate vessels for cannulation, and performing a central venous access procedure. Additionally, a deep vein thrombosis (DVT) option allows users to learn to identify the presence of thrombus in the deep vessels. 

Excellent realism and ultra-durable.

We know that gaining proficiency in using ultrasound requires practice.  Blue Phantom's self-healing tissue will allow you to repeatedly perform ultrasound-guided saphenous and femoral vascular access and ablation procedures without giving a second thought to wearing out the tissue or calculating the cost per cannulation. Whether you are learning to guide the needle to the targeted vessel or performing the entire ultrasound-guided central catheter insertion procedure, you can expect unmatched durability from our tissue and vessels.

This ultrasound training mannequin is constructed using Blue Phantom’s patented ultra-durable tissue and is extremely realistic in ultrasound imaging characteristics and feels like real human tissue.  Our self-healing tissue will withstand tremendous use and will save you money by dramatically reducing the necessity for purchasing replacement parts.

Practice to access and perform procedures on our realistic ultrasound training model.

Use ultrasound to identify and target anatomically correct vascular anatomy of the upper and mid-leg including the saphenous and femoral veins and tributary veins.  All of the vessels accommodate full threading of guidewires and catheters and is perfect for teaching and demonstrations for sapheno-venous ablation procedures.  Excellent for new users as well as more experienced users who are refining their vascular access procedural skills, the vessels in this venous access medical training mannequin can be accessed with needles as well as fluid can be injected into the model to verify needle tip location.  Injected fluids are automatically expelled so that the model can be used repeatedly for training.
 
Blue Phantom expend tremendous effort to match the imaging characteristics of real human tissue allowing you to teach and train under optimal conditions.  We know that the best simulation training scenarios are requisite on users experiencing the same procedural realism as performing the procedure on patients.  All of our simulation materials match the acoustic characteristics of real human tissue so when you use your ultrasound system on our training models, you experience the same quality you expect from imaging patients in a clinical environment.

This medical simulation trainer will perform well using any ultrasound imaging system configured with the appropriate transducer (recommended ultrasound transducer; high-frequency linear array ultrasound probe 5.0 – 12 MHz).  This ultrasound phantom model is excellent for specialities including anesthesiology (anaesthesiology), emergency medicine, cardiology, critical care medicine, radiology, surgery, surgical training programs, ultrasound training programs, simulation centres, surgical skills centres, medical education facilities, and ultrasound manufacturers for ultrasound education and demonstrations.  
   
Realistic and ultra-durable saphenous and femoral vascular access ultrasound training model excellent for training clinicians in the psychomotor skills associated with ultrasound-guided procedures.

Specifications:

  • Saphenous, femoral and accessory vessels are present in this venous access ultrasound training model mannequin
  • Superb ultrasound imaging characteristics
  • Ultra-durable self-healing tissue is extremely realistic in ultrasound imaging characteristics and feels like real human tissue
  • Self-healing tissue will withstand tremendous use and will save you money by dramatically reducing the necessity for purchasing replacement parts
  • Contains anatomically correct vascular anatomy of the right upper and mid-leg including the saphenous, femoral and tributary veins
  • Deep Vein Thrombosis in femoral vein (option)
  • Anatomical landmarks of the right leg
  • Accommodates full threading of guidewires and catheters
  • Positive fluid flow in the vessels provides users with immediate feedback when vessels are accessed
  • Tissues match the acoustic characteristics of real human tissue so when you use your ultrasound system on our training models, you experience the same quality you expect from imaging patients in a clinical environment
  • Performs well using any ultrasound imaging system
  • Practice using ultrasound system controls
  • Purchase includes 1 bottle of simulated blood refill solution; one red 235mls bottle
  • High quality
  • No special storage needs
  • Patented technology
  • Extremely durable; use for repeated training
  • Purchase includes 1 bottle of simulated blood refill solution; one red 235mls bottle
  • Size 32” x 8” x 8” (81cm x 20cm x 20cm) (L x W x H)
  • Weight 25 lbs. (11.5 Kg.)
  • Made in the USA

Deep Vein Thrombosis (DVT) Option

  • Add a thrombus in the femoral vein to help users identify the appearance of a thrombus in the deep venous system of the femoral vein. The DVT is non-compressible. Also excellent for experiencing resistance to threading guidewires and catheters due to deep vein thrombosis (DVT).

What's in the Box

  • Femoral and Saphenous Vein Leg Model includes:
    • Flex Foam Base Platform
    • Ultrasound Tissue Insert with Saphenofemoral Vessels (Part Number BPLI405)
  • Red Ultrasound Refill Solution (235 ml bottle)
  • User Guide
Leg Femoral and Saphenous Vein Venous Access Ultrasound Training Model with DVT Option User Manual - Sim & Skills

Optional Accessories (not included) 

  • Hard Storage Case for Leg Models (Part Number BPL402)
  • Additional Ultrasound Refill Solution:
    • Red Ultrasound Refill Solution (Part Number BRS180-Red)
  • Accessory Tissue Inserts:
    • Foreign Body Identification Accessory Tissue Insert (Part Number BPLI410)
    • Soft Tissue Mass Biopsy Accessory Tissue Insert (Part Number BPLPI420)
Sim & Skills accepts NHS, Government, and University Purchase Orders
Purchase Orders Accepted

click 'get a quote'

Free Returns

risk-free 28-day returns

Free Delivery when you spend £60 on web orders to GB Mainland Addresses | Sim & Skills
Free Delivery

when you spend £60+

Sustainability

reduce, re-use, recycle