Paediatric Regional Anaesthesia and Central Line Ultrasound Training Model
Safety & Quality
Safety & Quality
👉 This product is for training purposes only.
❓ It is unknown if this product contains Latex.
✅ Sim & Skills is ISO 9001 certified.
✅ Available via NHS Supply Chain.
Delivery
Delivery
When will my order arrive?
Items listed as In Stock are usually delivered in 1-3 working days.
Due to global supply chain disruption, some products are taking longer to deliver. If your order is affected, we will inform you as soon as possible with an estimated lead time or an alternative product recommendation.
For urgent or high volume orders, please contact us before placing your order to check stock availability.
How much does delivery cost?
Tracked Delivery on website orders to a single Mainland Great Britain address is charged at £7.50 + VAT.
Tracked Delivery on purchase orders to a single Mainland Great Britain address is charged at £15.00 + VAT.
Shipping to Northern Ireland and British Forces is charged at £25.00 + VAT.
Palletised deliveries are charged at £85.00 + VAT per pallet.
Deliveries will be made to a Goods In area not a specific room/department.
International shipping is provided on a case-by-case basis, please contact us for a quote.
Returns
Returns
What is the returns policy?
Returns are acceptable within 28 days of delivery (by law you have 14 days to notify us and a further 14 days to complete the return), providing the item is in a resalable condition and in its undamaged original packaging.
Cancellations and Returns are free of charge for items up to 20 kg. Collection for items over 20 kg will be quoted on a case-by-case basis.
All returns must be pre-authorised prior to shipping. Unauthorised returns may be refused and additional carriage costs may be incurred.
Failure to return goods in a resalable condition may result in a restocking fee of £25.00 + VAT or 20% of the invoice value, whichever is greater.
Any goods returned for product defect or warranty issues will not incur a restocking fee, but must still have appropriate authorisation.
To start a return, email orders@simandskills.com.
If your return is accepted, we’ll send you a return shipping label and instructions on how and where to send your package. Items sent back to us without first requesting a return will not be accepted.
Description
Description
Paediatric Regional Anaesthesia and Central Line Ultrasound Training Model
Blue Phantom’s Paediatric Ultrasound Central Line and Regional Anaesthesia Training Model is the most realistic central line and nerve block simulator available anywhere.
Using the innovative LifeCast™ modelling approach, the model provides the most realistic external landmarks while the internal anatomy is based on digital human files of a 6-year-old child.
This ultra-durable manikin incorporates all the anatomy required to gain proficiency in using ultrasound for paediatric central line placement and peripheral nerve blocks. This model is excellent for both ultrasound-guided and blind insertion central line procedural training.
Our ultra-durable self-healing tissue withstands tremendous use, minimizing the need for replacement parts. Blue Phantom allows clinicians to teach, practice and learn central line and regional anaesthesia procedures repeatedly without the need to worry about cost per use. Perform complete central line placements of the internal jugular and subclavian vein - including needles, guidewires, dilation, and threading of catheters.
Our realism makes your training better.
Blue Phantom’s simulated tissue, SimulexUS™, matches the acoustic properties of human tissue, providing clinicians with an extremely realistic training scenario. Use your ultrasound system without having to adjust the ultrasound system controls unrealistically. No computer simulation or software is necessary. Each of our training models is designed to offer users of all levels superior realism, reliability and durability.
Better training at a lower cost.
Paediatric Regional Anesthesia Central Line Model offers anatomically correct brachial plexus and vascular access anatomy of the upper thorax and neck. This next-generation ultrasound mannequin contains improved anatomy for nerve blocks including the supraclavicular nerves, interscalene nerves, infraclavicular nerves and enhanced access of the posterior interscalene nerve block approach.
Vascular access anatomy includes the internal jugular vein (IJ), brachiocephalic vein, subclavian vein, axillary vein, carotid artery, subclavian artery and axillary artery. The model can be accessed via the internal jugular (IJ), subclavian, infraclavicular and supraclavicular approach as well as the axillary vein.
The simulated superior vena cava, right atrium and right ventricle offer users the ability to fully thread guidewires, dilators and catheters without resistance just as you would expect with a live patient. The paediatric central line simulator also includes internal landmarks such as the trachea, suprasternal notch, manubrium and clavicle.
This model is excellent utilising traditional external landmarks for blind insertion central line placement or using ultrasound to guide the central venous access procedure. The brachial plexus can be injected with simulated anaesthetics to verify needle tip location and to practice the entire anaesthesia procedure. Injected simulated anaesthetics are expelled allowing for repeated use.
Arterial pulsation can be simulated via the manual hand bulb to differentiate between arteries and veins via ultrasound. Users can also add the optional fully integrated automated pump system for additional ease. The veins in our adolescent central line mannequin are also compressible using mild pressure while the arteries remain uncompressed.
Vessel identification is made easy by the immediate positive fluid flow of the vein versus artery. The venous system is prefilled with blue fluid and the arterial system is prefilled with red fluid.
Users can positively identify the targeted vessels and receive immediate feedback as to successful or unsuccessful vascular access. Re-fill venous and arterial fluid removed during central venous catheter procedures by using the provided QuickFill™ ports or an I.V. bag to continually refill the vessels during training.
- Paediatric upper torso ultrasound central line and regional anaesthesia manikin
- Extremely realistic external and internal anatomy for ultrasound-guided or blind insertion training on a 6-year-old patient
- Excellent for training clinicians in the psychomotor skills associated with ultrasound-guided central line placement training
- Superb imaging characteristics optimize your training; simulated tissue matches the acoustic properties of real human tissue
- For use with any ultrasound system, no computer simulation or software necessary
- Self-healing tissue offers users tremendous durability – minimizing the need for replacement parts and providing a low cost of ownership
- Anatomy:
- Regional anaesthesia anatomy includes: supraclavicular nerves, interscalene nerves, infraclavicular nerves and enhanced access of the posterior interscalene nerve block approach
- The brachial plexus can be injected with simulated anaesthetics to verify needle tip location and to practice the entire anaesthesia procedure
- Injected simulated anaesthetics are expelled allowing for repeated use
- Venous anatomy includes: internal jugular vein (IJ), brachiocephalic vein, subclavian vein and axillary vein
- Arterial anatomy includes: carotid artery, subclavian artery and axillary artery
- Simulated superior vena cava, right atrium and right ventricle allows clinicians to fully thread guidewires and catheters without resistance
- Internal landmarks for superior realism include the trachea, manubrium and clavicle
- Regional anaesthesia anatomy includes: supraclavicular nerves, interscalene nerves, infraclavicular nerves and enhanced access of the posterior interscalene nerve block approach
- Veins are compressible using mild pressure while the arteries remain uncompressed
- Arterial pulsations simulated using provided hand bulb or optional integrated automated pumping system
- Positive fluid flow in the vessels; model is prefilled with red fluid in the arteries and blue fluid in the veins
- Easy to refill vessels with ultrasound refill solution using QuickFill™ ports
- Excellent imaging quality using any ultrasound system
- Practice using ultrasound system controls
- No special storage needs
- Patented technology
- Purchase includes 2 bottles of simulated blood refill solution; one red (arterial), one blue (venous). 235mls each bottle
- Soft storage included
- Weight 8 pounds (3.6 kg)
- Dimensions: 13 x 7 x 16 (L x W x H inches)
- Made in the USA
Specifications
Specifications
-
Manufacturer's Warranty1 Year
Reviews (0)
Reviews (0)
Payment & Security
Secure payment methods
Your payment information is processed securely. We do not store or have access to your credit card details.
Purchase Orders
We accept purchase orders from public and government authorities including the NHS and Universities subject to our terms of business.
Click Add to Quote to easily build your quote ➡️